If you have been reading about Stenabolic and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Updated 2025-11-24. Numbers and descriptions here follow the published literature rather than marketing material.
SR9009 is frequently discussed alongside other REV-ERB ligands, including synthetic agonists and natural heme-related molecules. Its selectivity for REV-ERB over related nuclear receptors has been measured in binding and reporter assays, though off-target activity at higher concentrations is possible. The compound is prohibited in sport by the World Anti-Doping Agency, and it is not approved for any medical use in major jurisdictions. Products sold online may be labeled as research chemicals, and their identity and purity are not guaranteed by regulatory review.
SR9009 is a synthetic small molecule that acts on the nuclear receptors REV-ERBα and REV-ERBβ. These receptors are part of the circadian clock machinery and normally repress transcription of certain target genes. In laboratory research, SR9009 is used as a chemical tool to study how REV-ERB activity influences metabolism, inflammation, and daily biological rhythms. The compound is not an approved medicine, and its effects in humans remain largely uncharacterized. It is often described as an investigational agent rather than a therapeutic product.
Stability depends on physical form, temperature, light exposure, and solvent. Solid SR9009 is generally stored cold and dry, with protection from light to limit degradation. Dimethyl sulfoxide stocks are common for laboratory work, but repeated freeze-thaw cycles can reduce compound integrity. Aqueous solutions may be less stable than organic stocks, and the ethyl ester in the structure can be susceptible to hydrolysis under certain conditions. Researchers typically validate storage conditions and recheck purity before quantitative experiments, especially when using archived material.
Regulatory treatment of SR9009 varies by country and region. It is not approved as a pharmaceutical, and several jurisdictions restrict its sale for human consumption. Some authorities classify it as a research chemical, a prescription-only substance, or a prohibited performance-enhancing agent in sport. Purchasers may encounter certificates of analysis, but these documents do not guarantee identity, purity, or legality. In research settings, institutional safety reviews and controlled procurement help ensure that materials are handled under appropriate oversight. The absence of harmonized rules means that legal status can change and requires verification.
Analytical identification of SR9009 typically relies on liquid chromatography coupled with tandem mass spectrometry. In biological samples, researchers first separate the compound from matrix components using protein precipitation, liquid-liquid extraction, or solid-phase extraction. High-performance liquid chromatography with ultraviolet detection and nuclear magnetic resonance spectroscopy can support structural confirmation of reference materials. Because SR9009 is a small, relatively lipophilic molecule, reverse-phase columns and acidic mobile phases are common. Laboratories often include isotope-labeled internal standards to improve quantification and to correct for ion suppression.
| Property | Value | Notes |
|---|---|---|
| Common name | SR9009 | Also marketed informally as Stenabolic |
| Chemical class | Synthetic REV-ERB agonist | Binds REV-ERBα and REV-ERBβ |
| Molecular formula | C24H30ClN3O4S | Approximate molecular weight 492 g/mol |
| CAS Registry Number | 1379686-30-2 | Identifier for the parent compound |
| Regulatory status | Not approved for human use | Prohibited in sport by WADA |
Analytical chemists detect SR9009 with liquid chromatography-tandem mass spectrometry, commonly abbreviated LC-MS/MS. Sample preparation may involve protein precipitation, liquid-liquid extraction, or solid-phase extraction before analysis. Laboratories can target the parent compound or its metabolites, depending on the matrix and the purpose of testing. Anti-doping methods require sensitive and specific assays because concentrations in biological samples can be low. Reference standards and validated methods are essential for reliable identification and quantification.
Regulatory agencies have not approved SR9009 for human therapeutic use. It is typically sold as a research chemical with labels stating that it is not for human consumption. The World Anti-Doping Agency prohibits the substance in sport, generally under the category of non-approved substances. Customs and national laws may restrict importation, sale, or possession. Product quality and legal status can vary by country and vendor, and therapeutic claims are not permitted in regulated advertising because the compound lacks approval.
In laboratory settings, SR9009 is commonly identified by its molecular structure and its interaction with REV-ERB receptors. Vendors may list it under synonyms such as Stenabolic or REV-ERB agonist, but those names do not define purity or identity. Analytical confirmation typically uses high-performance liquid chromatography with ultraviolet detection or liquid chromatography–mass spectrometry. A reference standard is needed to compare retention time and mass spectrum, because the compound can be confused with related research chemicals.
Handling practices for SR9009 focus on minimizing degradation and contamination. The solid is generally stored desiccated at or below -20 °C, protected from light and moisture. Stock solutions are often prepared in dimethyl sulfoxide or ethanol, then aliquoted to avoid repeated freeze–thaw cycles. Aqueous solubility is low, so formulations for animal studies may require cosolvents or suspending agents. Personnel should follow institutional chemical safety procedures, because toxicological data for humans are incomplete.
Regulatory status varies by country and intended use. Major drug agencies have not granted marketing authorization for SR9009 as a medicine, and it is not listed as a controlled substance in many jurisdictions. It is often sold as a research chemical, a category that may fall outside pharmaceutical manufacturing rules. Buyers should verify local laws and supplier documentation, including certificates of analysis. The lack of standardized quality controls raises concerns about identity, purity, and actual content in products marketed online.
SR9009 is a synthetic small molecule studied as an agonist of REV-ERB nuclear receptors. REV-ERB alpha and REV-ERB beta help regulate circadian rhythms and metabolic gene expression. In laboratory research, SR9009 has been used to probe how these receptors affect skeletal muscle, liver, and adipose tissue. The compound was identified in academic drug-discovery work and is often described in scientific literature by its chemical name and research code. It is not an approved medicine, and human clinical data remain limited or absent.
SR9009 binds REV-ERB receptors and alters their repressive activity on target genes. This action can change transcription of genes involved in lipid handling, glucose metabolism, and mitochondrial function. In rodent studies, treated animals have shown changes in muscle oxidative capacity and exercise performance, though effects vary by dose, duration, and model. The precise molecular steps connecting receptor binding to whole-body outcomes are still an active area of investigation. Findings in animals do not automatically translate to humans.
== Prognosis == The individual may experience psychological trauma and emotional discomfort. The stump will remain an area of reduced mechanical stability. Limb loss can present significant or even drastic practical limitations. A large proportion of amputees (from 50 to 80% to 80–100%, according to different studies) experience the phenomenon of phantom limbs; they feel body parts that are no longer there. These limbs can itch, ache, burn, feel tense, dry or wet, locked in or trapped or they can feel as if they are moving. Some scientists believe it has to do with a kind of neural map that the brain has of the body, which sends information to the rest of the brain about limbs regardless of their existence. Phantom sensations and phantom pain may also occur after the removal of body parts other than the limbs, e.g. after amputation of the breast, extraction of a tooth (phantom tooth pain) or removal of an eye (phantom eye syndrome). A similar phenomenon is an unexplained sensation in a body part unrelated to the amputated limb. It has been hypothesized that the portion of the brain responsible for processing stimulation from amputated limbs, being deprived of input, expands into the surrounding brain, (Phantoms in the Brain: V.S. Ramachandran and Sandra Blakeslee) such that an individual who has had an arm amputated will experience unexplained pressure or movement on his face or head. In many cases, the phantom limb aids in adaptation to a prosthesis, as it permits the person to experience proprioception of the prosthetic limb.
=== 2.1a === VESA announced version 2.1a of the DisplayPort standard on 8 January 2024. This version replaces the DP40 cable certification with the new DP54 certification, which tests DisplayPort cables for proper operation at the UHBR13.5 (54 Gbit/s) speed introduced in version 2.0.
Australian labour law sets the rights of working people, the role of trade unions, and democracy at work, and the duties of employers, across the Commonwealth and in states. Under the Fair Work Act 2009, the Fair Work Commission creates a national minimum wage and oversees National Employment Standards for fair hours, holidays, parental leave and job security. The FWC also creates modern awards that apply to most sectors of work, numbering 150 in 2024, with minimum pay scales, and better rights for overtime, holidays, paid leave, and superannuation for a pension in retirement. Beyond this floor of rights, trade unions and employers often create enterprise bargaining agreements for better wages and conditions in their workplaces. In 2024, collective agreements covered 15% of employees, while 22% of employees were classified as "casual", meaning that they lose many protections other workers have. Australia's laws on the right to take collective action are among the most restrictive in the developed world, and Australia does not have a general law protecting workers' rights to vote and elect worker directors on corporation boards as do most other wealthy OECD countries. Equal treatment at work is underpinned by a patchwork of legislation from the Fair Work Act 2009, Racial Discrimination Act 1975, Sex Discrimination Act 1984, Disability Discrimination Act 1992, Age Discrimination Act 2004 and a host of state laws, with complaints possible to the Fair Work Commission, the Australian Human Rights Commission, and state-based regulators.
Abnormal thyroid function—hypo- and hyperthyroidism—can manifest as myopathy with symptoms of exercise-induced muscle fatigue, cramping, muscle pain and may include proximal weakness or muscle hypertrophy (particularly of the calves). Hypothyroidism up-regulates glycogen synthesis and down-regulates glycogenolysis and glycolysis; conversely, hyperthyroidism does the reverse, up-regulating glycogenolysis and glycolysis while down-regulating glycogen synthesis. Prolonged hypo- and hyperthyroid myopathy leads to atrophy of type II (fast-twitch/glycolytic) muscle fibres, and a predominance of type I (slow-twitch/oxidative) muscle fibres. Muscle biopsy shows abnormal muscle glycogen: high accumulation in hypothyroidism and low accumulation in hyperthyroidism. Hypothyroid myopathy includes Kocher-Debre-Semelaigne syndrome (childhood-onset), Hoffman syndrome (adult-onset), myasthenic syndrome, and atrophic form. In patients with increased growth hormone, muscle biopsy includes, among other features, excess glycogen deposition. EPG5-related Vici syndrome is a multisystem disorder, a congenital disorder of autophagy, with muscle biopsy showing excess glycogen accumulation, among other myopathic features. It is interesting to note, in comparison to hypothyroid myopathy, that McArdle disease (GSD-V), which is by far the most commonly diagnosed of the muscle GSDs and therefore the most studied, has as its second highest comorbidity endocrine disease (chiefly hypothyroidism) and that some patients with McArdle disease also have hypertrophy of the calf muscles.
Sources: en.wikipedia.org
6 June – BBC News reports that opposition to the Terminally Ill Adults (End of Life) Bill is growing among MPs, with a number who voted for it or abstained now saying they will vote against it. Following criticism of her performance at Prime Minister's Questions, Kemi Badenoch says she is "going to get better" as her party's leader, and is not "shy about self-criticism". Nathaniel Fried tells Politics South East that he resigned as head of Reform UK's Doge effort because the departure of Zia Yusuf left him with "a bit of doubt" about the project's future. Alexander Walker, the youngest member of Rhyl Town Council, is elected as the town's mayor at the age of 25. 7 June – Zia Yusuf announces he will return to Reform UK two days after resigning, and will run its Doge team. 8 June – The UK government says it intends to spend £86bn on the science and technology sector by the end of the current parliament. Reform's deputy leader, Richard Tice, insists the party knows "exactly what it is doing" following Zia Yusuf's departure and return. Speaking on BBC Scotland's Sunday Show, Scottish Labour leader Anas Sarwar accuses the Scottish National Party of running a "dishonest and disgraceful" campaign ahead of the Hamilton, Larkhall and Stonehouse by-election by attempting to push voters towards Reform UK, whose candidate came third in the election.
As of September 11, 2017, Teva remained the "world's biggest seller of generics medicines." On September 11, 2017, it was reported that they had selected Kåre Schultz as the new Teva CEO. A day later the company announced it would sell its Paragard contraceptive brand to Cooper Cos for $1.1 billion, with the funds being used to pay down debt. Days later the company announced further divestments: a sale of contraception, fertility, menopause and osteoporosis products to CVC Capital Partners Fund VI for $703 million and its emergency contraception brands for $675 million to Foundation Consumer Healthcare. By December, the company had announced a drastic 25 percent workforce reduction (greater than 14,000 employees) as part of a two-year cost-reduction strategy. Following considerable lobbying by the Israeli Government, from whom Teva received considerable tax breaks, and from Israel's labor federation, the Histadrut, Teva agreed to delay some of the layoffs in Israel. In October 2019, Teva faced criticism for making a "business decision to discontinue the drug" Vincristine, essential for the treatment of most childhood cancers according to the Food and Drug Administration.
The 2021 Romanian political crisis led to the ousting of Florin Cîțu's incumbent government. The Ciucă Cabinet then took power, with Romania since having experienced a shift towards authoritarianism and illiberalism, as well as an increased corruption. Around this time, Romania was also hit by the COVID-19 pandemic. In the 2024 presidential election, Independent candidate Călin Georgescu achieved a surprise win in the first round. However, the Constitutional Court annulled the election results, citing Russian meddling. The cancellation led to far-right protests, criticism by the Trump administration, and Ilie Bolojan becoming acting president in February 2025 as Iohannis resigned to political pressure. In the subsequent 2025 Romanian presidential election, Bucharest Mayor Nicușor Dan was elected president.
Sources: en.wikipedia.org
SR9009 is a synthetic research compound that binds and modulates the nuclear receptors REV-ERBα and REV-ERBβ. It is used in laboratory studies of circadian biology and metabolism, not as an approved medicine. It is also known by the informal name Stenabolic.
No. SR9009 has not been approved as a therapeutic drug in the United States, European Union, or other major markets. Human safety and efficacy data are very limited. Its presence in consumer products does not imply regulatory approval.
The World Anti-Doping Agency lists SR9009 as a prohibited substance because it can alter gene expression and metabolic pathways relevant to performance. The ban applies at all times, not only during competition. Detection relies on laboratory methods such as mass spectrometry.
The most common approach is liquid chromatography-tandem mass spectrometry, often after extraction from blood, urine, or tissue. Ultraviolet detection and nuclear magnetic resonance spectroscopy are used mainly for reference material characterization. Isotope-labeled internal standards improve accuracy.